Simulations were done at five degree intervals. The runs became unsuccessful under 85 K because there were not enough phase transfers. The experimental data was taken from IUPAC, volume 6 table 4 (pgs. 230-232)
T | RhoL Gibbs | RhoG Gibbs | RhoL Experiment | RhoG Experiment | Input | Results |
---|---|---|---|---|---|---|
(K) | (kg m-3) | (kg m-3) | (kg m-3) | (kg m-3) | File | File |
85 | 770.6 ± 3.986 | 7.074 ± 0.8571 | 771.8 | 9.829 | input 85 | results 85 |
90 | 746.7 ± 3.435 | 12.71 ± 0.8637 | 746.0 | 15.08 | input 90 | results 90 |
95 | 719.4 ± 6.235 | 16.93 ± 0.7418 | 718.4 | 22.27 | input 95 | results 95 |
100 | 701.6 ± 3.790 | 27.07 ± 1.776 | 688.7 | 31.93 | input 100 | results 100 |
105 | 669.5 ± 6.385 | 39.44 ± 3.373 | 656.2 | 44.89 | input 105 | results 105 |
90 | 746.7 ± 3.435 | 12.71 ± 0.8637 | 746.0 | 15.08 | input 90 | results 90 |
95 | 719.4 ± 6.235 | 16.93 ± 0.7418 | 718.4 | 22.27 | input 95 | results 95 |
100 | 701.6 ± 3.790 | 27.07 ± 1.776 | 688.7 | 31.93 | input 100 | results 100 |
105 | 669.5 ± 6.385 | 39.44 ± 3.373 | 656.2 | 44.89 | input 105 | results 105 |
110 | 635.9 ± 6.365 | 50.42 ± 2.897 | 620.1 | 62.42 | input 110 | results 110 |
115 | 611.4 ± 5.408 | 76.39 ± 4.071 | 578.1 | 86.96 | input 115 | results 115 |
120 | 561.3 ± 13.51 | 93.25 ± 2.351 | 525.1 | 124.5 | input 120 | results 120 |