Simulations were done at five degree intervals. The runs became unsuccessful under 105 K because there were not enough phase transfers. The run at 100 K was not used to fit the data since it only had 600 phase transfers. The experimental data was taken from the Handbook of Physical Properties of Liqids and Gases Second Edition, Chapter 6, N.B. Vargaftik Hemishphere Publishing Corp. 1975.
T | Rho L Gibbs | Rho G Gibbs | Rho L Experiment | Rho G Experiment | Input | Results |
---|---|---|---|---|---|---|
(K) | (kg m-3) | (kg m-3) | (kg m-3) | (kg m-3) | File | File |
100 | 1092 ± 6.636 | 9.213 ± 0.6606 | 1086.5 | 10.48 | input 100 | results 100 |
105 | 1063 ± 6.617 | 12.79 ± 1.111 | 1059.7 | 15.20 | input 105 | results 105 |
110 | 1034 ± 5.988 | 18.75 ± 2.316 | 1031.5 | 21.36 | input 110 | results 110 |
115 | 1007 ± 5.376 | 24.24 ± 0.9515 | 1001.6 | 29.28 | input 115 | results 115 |
120 | 985.2 ± 9.090 | 37.10 ± 1.651 | 969.9 | 39.34 | input 120 | results 120 |
125 | 943.4 ± 8.006 | 47.16 ± 2.131 | 934.6 | 52.06 | input 125 | results 125 |
130 | 909.7 ± 10.01 | 61.71 ± 3.902 | 896.1 | 68.17 | input 130 | results 130 |
135 | 863.1 ± 9.656 | 72.63 ± 5.179 | 854.7 | 88.89 | input 135 | results 135 |
140 | 828.7 ± 14.87 | 103.5 ± 7.416 | 808.4 | 116.1 | input 140 | results 140 |
145 | 757.8 ± 27.03 | 133.2 ± 9.272 | 750.8 | 153.9 | input 145 | results 145 |
150 | 706.0 ± 27.03 | 163.1 ± 3.660 | 672.5 | 212.5 | input 150 | results 150 |