SPC
Calculation of two points on the phase envelope of SPC water by GEMC-NVT
runs and comparison with the results of de Pablo et al., J. Chem. Phys.
93, 7355-7359 (1990) and Mezei, Mol. Sim., 9, 257-267
(1992). All runs were started in the two phase region from two boxes
with equal volume. The number of particles used in the simulation was N
= 300. The results were obtained by averaging over the last 2*106
steps (423 K) resp. 3.74*106 steps (523 K).
Code |
T(K) |
rholiq. (g/cm3) |
rhovap. (g/cm3) |
Upot., liq. (kcal/mol) |
Upot., vap. (kcal/mol) |
de Pablo et al. |
423 |
0.833(12) |
0.00275(15) |
-8.17(7) |
-0.46(10) |
Gibbs Project |
423 |
0.834(4) |
0.00266(41) |
-8.09(4) |
-0.45(31) |
de Pablo et al. |
523 |
0.658(25) |
0.0476(60) |
-6.64(15) |
-2.09(22) |
Gibbs Project |
523 |
0.656(16) |
0.0295(44) |
-6.45(14) |
-2.19(60) |
Code |
T(K) |
rholiq. (g/cm3) |
rhovap. (g/cm3) |
Alejandre et al. |
328 |
0.981 |
0.0001 |
Gibbs Project |
328 |
0.987(2) |
0.00002(1) |
Alejandre et al. |
479 |
0.815 |
0.0052 |
Gibbs Project |
479 |
0.811(9) |
0.0044(7) |
Go to: |
|
---|---|
Last modified by Johannes, July 31st 1996
Page created by Johannes, March 16th 1996